How Seismic Design Categories Are Determined for a Construction Site

Seismic design categories (SDCs) govern how a building must be designed for earthquake resistance. A building in SDC A has essentially no seismic requirements. A building in SDC D, E, or F must use special structural systems, detailed connections, and extensive engineering analysis. Understanding how SDC is determined helps contractors and owners anticipate the structural requirements for a project before design begins. Our seismic engineering services cover all SDCs across all 50 states.

What the Seismic Design Categories Are

ASCE 7 and the IBC define six seismic design categories: A through F. SDC A applies to areas with very low seismicity where the risk of a damaging earthquake is negligible. SDC B and C apply to moderate seismicity areas. SDC D, E, and F apply to high-seismicity areas including most of the western United States, Pacific Northwest, Alaska, parts of the Central and Eastern US, and Hawaii. The higher the SDC, the more stringent the seismic design requirements.

The SDC does not correspond exactly to a geographic region because it also depends on the occupancy of the building. Essential facilities like hospitals and emergency services buildings are assigned a higher SDC than standard occupancy buildings at the same location because they must remain functional after an earthquake. A hospital in a moderate seismicity area may have a higher SDC than a warehouse at the same location.

Step-by-Step: How SDC Is Determined

Step 1: Mapped Spectral Accelerations

The USGS National Seismic Hazard Model provides mapped spectral accelerations for locations across the United States. Two values are important: Ss, the mapped spectral response acceleration at short periods (0.2 seconds), and S1, the mapped spectral response acceleration at a 1-second period. These values represent the severity of ground shaking at the project site for a given return period. They are available through the USGS website and ASCE 7 tools. For our seismic retrofit and new building projects, we obtain these values from the authoritative source for the specific project location.

Step 2: Site Class Determination

Site class modifies the mapped spectral accelerations to account for the local soil conditions. Soft soils amplify ground motion compared to rock. ASCE 7 defines six site classes (A through F) based on the average shear wave velocity or standard penetration test values in the upper 100 feet of the soil profile. Site class is typically determined from the geotechnical report for the project.

Site Class A and B correspond to hard rock and rock. Site Class C is very dense soil or soft rock. Site Class D is stiff soil. Site Class E is soft clay. Site Class F requires site-specific response analysis and is used for very soft soils, liquefiable soils, and other special conditions. The geotechnical engineer makes the site class determination; the structural engineer applies it in the ASCE 7 SDC calculation.

Step 3: Site-Modified Spectral Accelerations

The site-modified spectral accelerations SDS and SD1 are calculated by multiplying the mapped spectral accelerations Ss and S1 by site amplification factors Fa and Fv respectively. These factors are tabulated in ASCE 7 based on the site class and the magnitude of the mapped accelerations. Soft soils (higher site class) have higher amplification factors, resulting in higher design spectral accelerations than the same location on rock.

Step 4: SDC Table Lookup

With SDS, SD1, and the occupancy category (Risk Category I through IV) determined, the SDC is found from ASCE 7 Table 11.6-1 and 11.6-2. The governing SDC is the more critical value from the two tables. Our structural engineering team performs this calculation for every project as part of the design criteria summary on the structural drawings.

What Changes Between SDCs

SDC A has no seismic requirements beyond those for any structure. SDC B has minimal requirements including some connection ductility provisions. SDC C adds requirements for nonstructural component anchorage and restricts the use of some structural systems. SDC D, E, and F require special detailing for concrete, steel, and masonry, restrict the structural systems that can be used above certain heights, mandate special inspection of seismic-force-resisting elements, and may require peer review for complex structures.

The seismic requirements in SDC D and above add significant cost and complexity to construction. Concrete shear walls in SDC D require special reinforcing detailing per ACI 318 Chapter 18. Steel moment frames in SDC D require special moment frame connections per AISC 341 seismic provisions. Masonry structures in SDC D have specific reinforcement and inspection requirements that do not apply in lower SDCs.

Why SDC Matters for Contractors

Understanding the SDC for a project helps contractors anticipate the level of structural complexity and the associated cost. A contractor bidding a structural concrete project in SDC D should expect more reinforcement, more special inspection requirements, and more complex connection details than a similar project in SDC B. Our engineering services include early consultation on SDC and its implications for projects where the seismic requirements are a significant cost driver.

Frequently Asked Questions

What is the SDC for a project in Los Angeles?

Most of Los Angeles County is SDC D, E, or F for standard occupancy buildings due to the high seismicity of the region and typical soil conditions. Essential facilities may be SDC F. The exact SDC depends on the specific location and site soil conditions, which must be evaluated by the geotechnical and structural engineers for each project.

Can a project be designed for a higher SDC than required?

Yes. An owner or design team may choose to design for a higher SDC than required, which is sometimes called enhanced seismic performance. This approach results in a building more likely to remain functional after an earthquake. It costs more upfront but may reduce post-earthquake repair costs and business interruption losses.

Does the SDC affect the required foundation type?

SDC affects foundation requirements primarily through restrictions on using spread footings in high seismic areas when liquefiable soils are present, and through requirements for grade beams or mat foundations to tie isolated footings together. The geotechnical report for SDC D and above projects must specifically address seismic hazards including liquefaction, lateral spreading, and slope instability.

Get Your Seismic Design Evaluated

We provide seismic analysis and structural engineering for all SDCs across all 50 states. Submit your project at rightangleeng.com/get-started.

References

American Society of Civil Engineers. (2022). ASCE 7-22: Chapter 11: Seismic Design Criteria. Reston, VA.

U.S. Geological Survey. (2023). National Seismic Hazard Maps. earthquake.usgs.gov.

International Building Code. (2021). Section 1613: Earthquake Loads. International Code Council.