The lateral-force-resisting system (LFRS) is the structural subsystem responsible for keeping a building from collapsing or becoming dangerously distorted when earthquake or wind forces act horizontally on the structure. Selecting and designing the LFRS is one of the most consequential decisions in structural engineering. Our seismic structural engineering team designs lateral systems for projects across all 50 states.
What Lateral Forces Are and Why They Matter
Gravity loads act downward. Beams, columns, and walls are all effective at carrying vertical loads. However, wind and earthquakes apply forces horizontally, which requires a different structural system. Most floor and roof framing that efficiently carries vertical loads is poor at resisting horizontal forces without specific design attention.
In an earthquake, the ground accelerates horizontally, and the mass of the building resists this acceleration through inertia. The result is a horizontal force on the building proportional to its weight and to the intensity of the ground acceleration. This seismic force must be transferred from every floor and roof level through the LFRS down to the foundation and into the ground. Without an adequate LFRS, a building can rack, collapse, or sustain severe structural damage.
The Main LFRS Types
Shear Walls
Shear walls are vertical structural panels that resist lateral loads through in-plane shear. Wood structural panel shear walls in wood-frame buildings, concrete shear walls in concrete buildings, and reinforced masonry walls are all common shear wall types. Shear walls are stiff, cost-effective lateral systems that work well when the architectural floor plan can accommodate them at appropriate locations. Our structural engineering team designs shear wall systems for buildings from single-story wood-frame to multi-story concrete.
Moment-Resisting Frames
Moment-resisting frames resist lateral loads through bending in beams and columns at specially designed rigid connections. The key feature is that the beam-to-column connection is designed to transfer moment (rotational force) so that the frame as a whole deforms laterally without the connections rotating freely. Steel special moment frames and concrete special moment frames are used in high-seismic design categories where ductility requirements preclude simpler systems.
Moment frames allow more open floor plans than shear wall systems because the lateral resistance is concentrated at the frame lines rather than distributed across wall panels. This architectural flexibility makes them popular for office buildings and retail spaces where open, column-free areas are important. The tradeoff is higher structural cost because moment frame connections are expensive to fabricate and inspect.
Braced Frames
Braced frames use diagonal steel members that act in tension or compression to resist lateral forces. The diagonals convert horizontal loads to axial forces in the bracing members, which steel carries very efficiently. Special concentrically braced frames (SCBF) and eccentrically braced frames (EBF) are the code-approved systems for high-seismic areas. Braced frames concentrate lateral resistance at specific bays, which allows the rest of the floor plan to remain open.
Dual Systems
A dual system combines a primary LFRS (typically a moment frame) with a secondary system (typically shear walls or braced frames). The two systems work together to share the lateral load, with the moment frame acting as a backup if the primary system is overstressed. Dual systems provide redundancy and are required or preferred in the highest seismic design categories for tall buildings. Our structural team designs dual systems for complex multi-story projects.
How Engineers Select the Appropriate LFRS
The selection process starts with the SDC (seismic design category) and the building height. ASCE 7 Table 12.2-1 lists the permitted structural systems for each seismic design category with applicable height limits. In SDC D, for example, ordinary shear walls are not permitted and the building must use special shear walls or moment frames. In SDC A, almost any system is permitted.
Floor plan constraints and architectural requirements also drive system selection. A building with long, open floor plates may not accommodate enough shear wall length for a shear wall-only system and may require moment frames at specific bays to supplement the shear wall system. The structural engineer and architect must collaborate to find a system that meets the code requirements within the architectural constraints.
Diaphragm Action
The LFRS only works if the floor and roof diaphragms effectively collect lateral forces from across the building and deliver them to the LFRS elements. A wood structural panel roof diaphragm, a concrete slab, or a metal deck with concrete fill all act as horizontal plates that distribute seismic and wind forces to the vertical LFRS elements at the edges. Diaphragm design is an integral part of the lateral system design. Our engineering work always includes explicit diaphragm design as part of the lateral system analysis.
Frequently Asked Questions
Can I switch from shear walls to a moment frame during the design to open up the floor plan?
Yes, but the switch must be evaluated by the structural engineer because changing the LFRS type can significantly affect the lateral design. Moment frames are typically more flexible than shear walls, which affects the building drift (how much it sways). If the drift exceeds code limits, adjustments to the frame stiffness are required. The engineer must confirm that the new system meets all code requirements before the change is incorporated.
How much does the LFRS type affect construction cost?
Special moment frames in SDC D are typically the most expensive LFRS option because of the cost of fabricating and inspecting the moment connections. Special shear walls are less expensive in most cases, but they consume floor area. The total cost comparison depends on the building type, size, SDC, and architectural requirements. The structural engineer can provide a cost-effectiveness comparison of system alternatives early in the design process.
What causes an LFRS to fail in an earthquake?
Common LFRS failure modes include inadequate connection ductility (connections fracture before the system can deform and dissipate energy), insufficient shear wall length or hold-down capacity, soft story conditions where one story is significantly weaker than adjacent stories, and diaphragm discontinuities that prevent effective force transfer to the LFRS. Seismic retrofit engineering addresses these failure modes in existing buildings.
Design Your Lateral System With Us
We design lateral-force-resisting systems and provide seismic engineering for buildings in all SDCs across all 50 states. Submit at rightangleeng.com/get-started.
References
American Society of Civil Engineers. (2022). ASCE 7-22: Chapter 12: Seismic Design Requirements for Building Structures. Reston, VA.
American Institute of Steel Construction. (2022). AISC 341-22: Seismic Provisions for Structural Steel Buildings. Chicago, IL.
American Concrete Institute. (2019). ACI 318-19: Chapter 18: Earthquake-Resistant Structures. Farmington Hills, MI.